Hi Team
Here's the concern regards with no putaway problem.
---------------------
Super 8 Malolos Prod
ASN: ASNNR2110000071
SKU: IND06
IND07
--------------------
Best Regards,
Jeric
On Fri, 15 Oct at 12:25 PM , Erica Mae M. Sanchez - FSC <emmsanchez@fastgroup.biz> wrote:
Hi
Team,
Can you help us check why there's no suggested putaway location in the
trace id and even in web ui. Actually all the items are affected and has
no suggested putaway locations.
Super 8 Malolos Prod
ASN: ASNNR2110000071
SKU: IND06
IND07
Thanks,
Erica
The issue is caused by the location master is missing the rack information which should be inputted in the field ‘LocGroup1’. This information is used by the putaway rule to search for an eligible location for putaway. Refer to screenshots below.
Files | ||
---|---|---|
|
DataImage11.png
99 KB
|
|
|
DataImage78.png
242 KB
|